Current Sense Amplifiers

ADI’s Current Sense Amplifiers offer excellent performance for a wide array of automotive and power management applications. These devices accurately amplify small voltages in the presence of large common-mode voltage, provide high bandwidth, as well as level shifting and bidirectional capability. Excellent DC and AC accuracy over a wide temperature range from -40°C to 125°C minimizes errors in your measurement loop while not sacrificing on cost and package size.
Also, the 3rd Edition of A Designer's Guide to Instrumentation Amplifiers is now available online and in print.

Loading Selection Table Data. Please wait...

Processing request. Please wait.

Help

  • Sort: Click on the arrows beneath the parameter on which you would like to sort, ascending and descending order.

  • Add/Remove Parameters: Click on the Add/Remove Parameters button. Select/deselect the checkbox of the parameter in the add/remove parameter pop up box. Click on "Update" for the table to redraw with new selection of parameters.

  • Filter: Enter the desired value to filter parameter(s) by, and click the "Update Results" button to update the table display.

  • Reset Table: Click "Reset Table" to clear all filters/sorts and restore table back to default view.

  • Quick Filters: When applicable, select a quick filter with preset parameters filtered to narrow the results returned.

Current Sense and Difference Amplifiers

Add/Remove Parameters













Part#
Results: 25
Common Mode Range (V)Bandwidth G=10 (kHz typ)CMRR (dB)Gain Range (min to max)Voltage Supply (Vmin)Voltage Supply (Vmax) Supply Current (max)VosiTC (µV/deg C)Gain temp co.Temperature RangePackagePrice* (1000-4999)
Sort
parameter
 
sortDescending sortAscending
sortDescending sortAscending
sortDescending sortAscending
sortDescending sortAscending
sortDescending sortAscending
sortDescending sortAscending
sortDescending sortAscending
sortDescending sortAscending
  
sortDescending sortAscending
Filter by value

           
AD22057-1 to 24308020+3+260.5mA---40 to +125DIP, SOIC $4.62
AD6260 to 541006690±2.4±62mA0.000006150ppm/C-40 to +85DIP, SOIC $3.70
AD628+/- 10060077100±5±181.6mA---40 to +85SOIC $1.78
AD629+/- 270500771±2.5±181mA---40 to +85DIP, SOIC $2.84
AD8202-12 to 30508220+3.5+120.25mA1020ppm/C-40 to +125Die, SOIC, SOP $1.51
AD8203-12 to 30608214+3.5+120.25mA1020ppm/C-40 to +125SOP $1.37
AD8205-2 to 65507850+4.5+52mA1530ppm/C-40 to +125Die, SOIC $1.51
AD8206-2 to 651007620+4.5+5.52mA1530ppm/C-40 to +125Die, SOIC $1.37
AD8210-2 to 6550010020+4.5+5.51.5mA1020ppm/C-40 to +125SOIC $1.81
AD8211-2 to 6550012020--2mA1220ppm/C-40 to +125SOT $0.81
AD82127 to 6510001001,000+7+65720µA10--40 to +125MSOP $0.93
AD8213-2 to 6550010020+4.5+5.52.5mA1210ppm/C-40 to +125MSOP $2.01
AD82145 to 65-80100+5+651.2mA15--40 to +125MSOP $0.76
AD8215-2 to 6545010020+4.5+5.52.2mA615ppm/C-40 to +125SOIC $1.21
AD8216-4 to 653000903+4.5+5.52mA1010ppm/C-40 to +125SOIC $1.62
AD8228-65010010,100+4.6+361mA---40 to +85- $3.03
AD8270-Vs to +Vs10000981.5+5+362.5mA1.51ppm/C-40 to +125- $1.89
AD8273+/- 4020000861.5+5+362.5mA32ppm/C-40 to +125- $1.67
AD8274+/-3Vs1000086-+5+362.6mA30.5ppm/C-40 to +85MSOP, SOIC $1.05
AD8275-13 to 24-960.2+3.3+152.3mA2.50.3ppm/C-40 to +85MSOP $1.60
AD8290--12050+2.6+5.54.68mA-15ppm/C-- $1.52
AD8295-7501401,000+4.6+362.3mA0.31ppm/C-40 to +85CSP $2.89
AD8553-110010,000+1.8+5.51.3mA---40 to +85MSOP $1.32
ADM40732 to 2818009040+3+28----40 to +125SOT $0.99
AMP03+/- 203000851±5±152.5mA---40 to +85- $2.81
Please scroll down to see more data.
back to top

Help

  • Sort: Click on the arrows beneath the parameter on which you would like to sort, ascending and descending order.

  • Add/Remove Parameters: Click on the Add/Remove Parameters button. Select/deselect the checkbox of the parameter in the add/remove parameter pop up box. Click on "Update" for the table to redraw with new selection of parameters.

  • Filter: Enter the desired value to filter parameter(s) by, and click the "Update Results" button to update the table display.

  • Reset Table: Click "Reset Table" to clear all filters/sorts and restore table back to default view.

  • Quick Filters: When applicable, select a quick filter with preset parameters filtered to narrow the results returned.

Power Monitoring

Add/Remove Parameters









Please scroll down to see more data.
back to top